Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
Quantitative determination of colistin A/B and colistin methanesulfonate in biological samples using hydrophilic
Bing Qi1, Matthias Gijsen2,3, Pieter Van Brantegem1
1Drug Delivery and Disposition, KU Leuven Department of Pharmaceutical and Pharmacological Sciences, Leuven, Belgium.
Abstract:
Colistin (polymyxin E) is a polycation antibiotic which is increasingly used (administered as colistin methanesulfonate, CMS) as a salvage therapy in critically ill patients with multidrug resistant Gram-negative infections. Even though colistin has been used for more than 50 years, its metabolic fate is poorly understood. One of the current challenges for studying the pharmacokinetics (PK) is the precise and accurate determination of colistin in in vitro and in vivo studies. In the present study, we developed and validated a series of sensitive and robust liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for analysing biological samples obtained from in vitro and in vivo disposition assays. After a zinc acetate-mediated precipitation, hydrophilic-lipophilic-balanced solid phase extraction (HLB-SPE) was used for the extraction of colistin. The compounds were retained on a hydrophilic interaction liquid chromatography (HILIC) column and were detected by MS/MS. CMS was quantified by determining the produced amount of colistin during acidic hydrolysis. The developed methods are sensitive with lower limits of quantification varying between 0.009 μg/mL and 0.071 μg/mL for colistin A, and 0.002 μg/mL to 0.013 μg/mL for colistin B. The intra- and inter-day precision and accuracy were within ±15%. Calibration curves of colistin were linear (0.063 μg/mL to 8.00 μg/mL) within clinically relevant concentration ranges. Zinc acetate-mediated precipitation and the use of a HILIC column were found to be essential. The developed methods are sensitive, accurate, precise, highly efficient and allow monitoring colistin and CMS in biological samples without the need for an internal standard.
More Related Videos
08:03A Tandem Liquid Chromatography–Mass Spectrometry-based Approach for Metabolite Analysis of Staphylococcus aureus
Published on: March 28, 2017
08:06Absolute Quantification of Cell-Free Protein Synthesis Metabolism by Reversed-Phase Liquid Chromatography-Mass Spectrometry
Published on: October 25, 2019