Related Experiment Video
Updated: Dec 23, 2025

Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
Phase unwrapping based on a residual en-decoder network for phase images in Fourier domain Doppler optical coherence
Chuanchao Wu1, Zhengyu Qiao1, Nan Zhang1
1School of Optics and Photonics, Beijing Institute of Technology, No. 5 South Zhongguancun Street, Haidian, Beijing 100081, China.
Abstract:
To solve the phase unwrapping problem for phase images in Fourier domain Doppler optical coherence tomography (DOCT), we propose a deep learning-based residual en-decoder network (REDN) method. In our approach, we reformulate the definition for obtaining the true phase as obtaining an integer multiple of 2π at each pixel by semantic segmentation. The proposed REDN architecture can provide recognition performance with pixel-level accuracy. To address the lack of phase images that are noise and wrapping free from DOCT systems for training, we used simulated images synthesized with DOCT phase image background noise features. An evaluation study on simulated images, DOCT phase images of phantom milk flowing in a plastic tube and a mouse artery, was performed. Meanwhile, a comparison study with recently proposed deep learning-based DeepLabV3+ and PhaseNet methods for signal phase unwrapping and traditional modified networking programming (MNP) method was also performed. Both visual inspection and quantitative metrical evaluation based on accuracy, specificity, sensitivity, root-mean-square-error, total-variation, and processing time demonstrate the robustness, effectiveness and superiority of our method. The proposed REDN method will benefit accurate and fast DOCT phase image-based diagnosis and evaluation when the detected phase is wrapped and will enrich the deep learning-based image processing platform for DOCT images.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Continuous -time Fourier Transform
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
Discrete-time Fourier transform
One of the notable...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Discrete Fourier Transform