Related Experiment Video
Updated: Dec 23, 2025

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Left Distal Transradial Access (ldTRA): A Comparative Assessment of Conventional and Distal Radial Artery Size
Anastasia Hadjivassiliou1, Leandro Cardarelli-Leite1, Sabeena Jalal1
1Department of Radiology, Vancouver General Hospital, 899 West 12th Avenue, Vancouver, BC, V5Z 1M9, Canada.
Purpose:
To assess left radial artery size, technical feasibility and safety of ldTRA in the anatomical snuffbox for percutaneous image-guided procedures.
Materials And Methods:
A retrospective single-center study was performed from November 2016 to June 2018 on all patients undergoing ldTRA for interventional radiology procedures.
Results:
A total of 287 patients (91 female and 196 male), aged 18-94 years (mean age 64 years), were included. 389 procedures were performed which included hepatic chemoembolization (n = 161), selective internal radiation therapy Y-90 mapping (n = 74), selective internal radiation therapy Y-90 administration (n = 48), diagnostic angiography (n = 34), mesenteric and pelvic embolization (n = 59), stent insertion (n = 8) and miscellaneous (n = 5). Mean sonographic measurement of the left radial artery size at the conventional site at the wrist was 2.55 mm (range 1.4-3.3 mm) and 2.34 mm (range 1.4-3.2 mm) at the anatomical snuffbox (p < 0.001). Technical success rate was 100%, a single small hematoma occurred in the first patient (0.3%). 74.2% of patients had follow-up for radial artery patency (mean 46 days, range 0-66 days), which did not reveal radial artery occlusions or pseudoaneurysm formation.
Conclusion:
The left distal radial artery in the anatomical snuffbox is smaller in comparison with the conventional access site at the wrist. The difference however is small and does not require intentional downsizing of vascular access equipment to facilitate utilization of ldTRA. Assessment of the vessel size is imperative for appropriate equipment selection and optimizing procedural success. This study supports that ldTRA is technically feasible and safe.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Arteries of the Upper Limbs
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...