Medical equipment trends during the UK military exercise SAIF SAREEA 3 in Oman
Daniel C Thompson1, L G Davies1, M B Smith2
15 Armoured Medical Regiment, British Army, Catterick Garrison, UK.
Introduction:
Ex SAIF SAREEA 3 was a joint British-Omani military exercise involving approximately 5500 British personnel deployed to Oman over a 6-month period. Role 1 medical care was provided by medical treatment facilities (MTFs) deployed with medical equipment as per the UK 300 medical module.
Method:
Retrospective analysis was undertaken of prospectively collected equipment usage data from two Role 1 MTFs in Duqm (MTF 1) and Muaskar Al Murtafa (MTF 2) camps over a period of 6-8 weeks. Data were analysed alongside routinely collected epidemiological data (EPINATO) during the deployment. Equipment used in addition to the module was also recorded.
Results:
MTF 1 used 50 out of the 179 different items from the module over the 8-week period. MTF 2 used 45 out of the 179 different items from their module over the 6-week period. The most commonly used items across the sites were non-sterile examination gloves, plastic aprons, tympanic thermometer probe covers, disinfectant wipes and self-adhesive plasters. Extramodular items (blunt fill needle, water pump sprayer, Jelonet gauze and stool specimen pot) accounted for 5% of all equipment used in MTF 1.
Conclusion:
The study showed that the 300 module accommodates 95% of Role 1 patients' needs but highlights the requirement for dedicated equipment for the treatment of heat casualties if deemed likely and blunt fill/filter needles for the administration of parenteral medication. Commanders must perform a thorough medical estimate and risk assessment prior to deployment to ensure that the 300 medical module is likely to provide the necessary equipment and supplement the module if required.
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
14:31Bioelectric Analyses of an Osseointegrated Intelligent Implant Design System for Amputees
Published on: July 15, 2009
Related Concept Videos
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...