Related Experiment Video
Updated: Dec 22, 2025

Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Simultaneous Determination of Six Chromones in Saposhnikoviae Radix via Quantitative Analysis of Multicomponents by
Jinhua Zhang1, Luxiao Chen1, Junna Qiu1
1College of Traditional Chinese Medicine, Beijing University of Chinese Medicine, Beijing 102488, China.
Abstract:
A method, quantitative analysis of multicomponents by single marker (QAMS), was established and fully verified based on high-performance liquid chromatography (HPLC) for simultaneous determination of six chromone indicators of Saposhnikoviae Radix (SR). In the present study, cimifugin (C), 5-O-methylvisamminol (V), hamaudol (H), and their corresponding glycosides, prim-O-glucosylcimifugin (GC), 4'-O-β-D-glucosyl-5-O-methylvisamminol (GV), and sec-O-glucosylhamaudol (GH), were selected as bioactive constituents and indicators for the quality evaluation of SR. GV was chosen as the unique reference standard, and relative correction factors (RCF) between GV and the other five chromones were calculated. The feasibility of QAMS for the analysis of chromones was investigated by comparing with the traditional external standard method (ESM). Furthermore, the method was proven to have accuracy (96.98%-102.50%), repeatability (RSD <3%), stability (RSD <3%), precision (RSD <3%), and desirable linearity (R 2 ≧0.9999). Subsequently, 55 batches of commercial SR from different regions were determined by QAMS, and their contents were analyzed by principal component analysis (PCA), correlation analysis, and hierarchical cluster analysis (HCA), respectively. Based on the results, a more refined quality standard of commercial SR was proposed: SR was qualified when the total contents of six chromones were greater than 3 mg·g-1. Furthermore, SR could initially be regarded as a superior medicine when it satisfied both conditions at the same time: the total content of GC, C, GV, V, GH, and H was greater than 8 mg·g-1, and the proportion of the total content of C, V, and H was greater than 10%. This study demonstrated that the quality of SR could be successfully evaluated by the developed QAMS method; meanwhile, valuable information was provided for improving the quality standard of SR.
More Related Videos
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021