Related Experiment Video
Updated: Dec 22, 2025

Ion Exchange Chromatography IEX Coupled to Multi-angle Light Scattering MALS for Protein Separation and Characterization
Published on: April 5, 2019
Fragment-based Design of Zwitterionic, Strong Cation- and Weak Anion-Exchange Type Mixed-mode Liquid Chromatography
Martina Ferri1, Stefanie Bäurer2, Andrea Carotti3
1Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, University of Tübingen, Auf der Morgenstelle 8, 72076 Tübingen, Germany; Department of Pharmaceutical Sciences, University of Perugia, Via del Liceo 1, 06123 Perugia, Italy.
Abstract:
The role of individual functional groups has been assessed with regard to surface charge and chromatographic retention. Coatings were prepared from various fragments of the chiral zwitterionic materials Chiralpak ZWIX(+) and ZWIX(-). The different chromatographic ligands allowed fine tuning of the surface charge. Chiralpak ZWIX phases showed strongly negative ζ-potentials over the entire pH-range. Zwitterionic congeners with quinuclidine and sulfonic acid moieties but lacking the quinolone ring in the ligand structure exhibited shifted ζ-potentials of around + 5 to 20 mV depending on the surrounding residues. Capillary electrophoretic mobilitiy measurements with the chromatographic ligands and molecular dynamics simulations were carried out to offer some explanation of these surface charge differences of the distinct zwitterionic stationary phases. The new mixed-mode phases were also chromatographically characterized by simple RP and HILIC tests. The results allowed their positioning within a large variety of different commercially available RP, HILIC and mixed-mode phases, which were evaluated as well, by multivariate data processing using principal component analysis. The new mixed-mode phases overall exhibit reasonable hydrophilicity-lipophilicity balance and enable retention of ionic compounds by additional ionic interactions through weak anion-exchange (WAX-type), strong cation-exchange (SCX-type) or both (RP/ZWIX-type). Hence, the new RP/ZWIX phases can be flexible tools for selectivity tuning in RP and HILIC separations.
More Related Videos
04:51Author Spotlight: Functionalizing Metal-Organic Frameworks: Advancements, Challenges, and the Power of Post-Synthetic Ligand Exchange
Published on: June 23, 2023
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Affinity Chromatography
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Extraction: Advanced Methods