A pharmacokinetic-pharmacodynamic real-time display may change anesthesiologists' behavior
Shinju Obara1, Noah Syroid2, Takahiro Ogura3
1Department of Anesthesiology, Fukushima Medical University, 1 Hikarigaoka, Fukushima, Fukushima, 9601295, Japan.
Abstract:
We have developed a real-time graphical display that presents anesthetic pharmacology data (drug effect site concentrations (Ce) and probability of anesthetic effects including hypnosis, loss of response to tracheal intubation), improving a previous prototype. We hypothesized that the use of the display alters (1) clinical behavior of anesthesiologists (i.e., Ce of isoflurane and fentanyl at the end of anesthesia), (2) fentanyl dose during the first 30 min of recovery in the post anesthesia care unit (PACU), and that the response of clinicians to the display in terms of workload and utility is favorable. The display was evaluated in a two-group, non-randomized prospective observational study of 30 patients undergoing general anesthesia using isoflurane and fentanyl. The isoflurane-predicted Ce was lower in the display group (without-display: 0.64% ± 0.06%; with-display: 0.42 ± 0.04%; t23.9 = 3.17, P = 0.004 < adjusted alpha 0.05/2). The difference in fentanyl-predicted Ce did not achieve statistical significance (without-display: 1.5 ± 0.1 ng/ml; with-display: 2.0 ± 0.2 ng/ml; t25.5 = 2.26, P = 0.03 > adjusted alpha 0.05/2) (means ± standard error). A joint test of isoflurane and fentanyl Ce with respect to the display condition rejected the null hypothesis of no differences (Hotelling T2, P = 0.01), supporting our primary hypothesis. The total fentanyl per patient during the first 30 min in the PACU with the display was 75.0 ± 62.7 µg and that without the display was 83.0 ± 74.7 µg. There was no significant difference between the groups (means ± standard deviation, P = 0.75). There were no differences in perceived workload. Use of the display does not appear to be cognitively burdensome and may change the anesthesiologist's dosing regimen.
More Related Videos
07:02A Computerized Test Battery to Study Pharmacodynamic Effects on the Central Nervous System of Cholinergic Drugs in Early Phase Drug Development
Published on: February 11, 2019
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
Related Concept Videos
Measurement of Bioavailability: Pharmacodynamic Methods
Local Anesthetics: Pharmacokinetics
Chronopharmacokinetics: Circadian Rhythms and Influence on Drug Response
The time of drug administration is an important factor to consider, as it can influence the toxic dose of a drug. For example, a study conducted by Prins et al. in 1997 examined the effects of the timing of...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Pharmacokinetics: Drug–Drug Interactions
Pharmacodynamics: Overview and Principles
Most drugs' effects result from their interactions with drug receptors or targets within the body. These interactions trigger specific responses at the cellular or systemic level. Drug receptors can be found on the surfaces of cells or...