Related Experiment Video
Updated: Dec 22, 2025

Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
Measurement of internal magnetic flux density distribution in air-core toroidal transformer under high-frequency
Kazuki Hashimoto1, Takafumi Okuda1, Takashi Hikihara1
1Department of Electrical Engineering, Kyoto University, Katsura, Nishikyo, Kyoto 615-8510, Japan.
Abstract:
An investigation of air-core toroidal transformers has been undertaken to enable power converters to achieve megahertz operation. The characteristics of the air-core toroidal transformer govern the behaviors of the internal magnetic flux of the transformer. Understanding the behaviors at an above-megahertz level is a key issue in the design of the air-core toroidal transformer. This paper discusses the internal magnetic flux density distribution in the air-core toroidal transformer under high-frequency excitation. We propose a measurement method for the distribution and show the obtained results under a sinusoidal excitation with an amplitude of 1.5 A and a frequency of 1 MHz. The results reveal a non-uniform distribution in the tangential and normal directions. The cause of this non-uniformity was found to be the structure of the air-core toroidal transformer. In addition, the validity of the proposed measurement method was confirmed by comparing the experimentally obtained results with a numerical estimation using the Biot-Savart law. These results suggest that the proposed measurement method is capable of investigating the distributed characteristics of air-core toroidal transformers under megahertz excitation.
Related Concept Videos
The Ideal Transformer
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's tangential...
Torque On A Current Loop In A Magnetic Field
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
Induced Electric Fields: Applications
Magnetic Field Of A Current Loop
Toroids
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb points in...
Energy In A Magnetic Field
Take an ideal inductor with zero resistance. Although it's practically impossible, assume that the coil's resistance is so small that it is practically negligible. The loss of the field's energy to dissipate thermal energy (or heat) is thus...