Related Experiment Video
Updated: Dec 22, 2025

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Scleral fixation of a single-piece foldable acrylic IOL through a 1.80 mm corneal incision
Daniele Veritti1, Lisa Grego, Francesco Samassa
1From the Department of Medicine-Ophthalmology, University of Udine (Veritti, Grego, Samassa, Sarao, Lanzetta), and Istituto Europeo di Microchirurgia Oculare (Veritti, Sarao, Lanzetta), Udine, Italy.
A new scleral fixation technique of a single-piece acrylic foldable intraocular lens (IOL) (enVista MX60, Bausch & Lomb, Inc.) through a 1.80 mm corneal incision, using the IOL eyelets as anchoring point, is described. It was a retrospective review of 26 cases. The preoperative mean corrected distance visual acuity was 0.51 ± 0.21 logarithm of the minimum angle of resolution (logMAR). It improved significantly to 0.25 ± 0.27 logMAR (P < .01), 0.18 ± 0.16 logMAR (P < .01), and 0.17 ± 0.16 logMAR (P < .01) (at 1 month, 3 months, and 6 months postoperatively, respectively, repeated measures analysis of variance, P < .0001). No astigmatism increase of more than 0.75 diopters was recorded at any time point. In all 26 patients, the IOL was well centered and stable for the entire monitoring period. No complications were observed during follow-up. Scleral fixation of the foldable IOL through a 1.80 mm corneal incision provided excellent IOL stability during the 6-month follow-up of this study and might be an effective and safe surgical technique.
A new scleral fixation technique of a single-piece acrylic foldable intraocular lens (IOL) (enVista MX60, Bausch & Lomb, Inc.) through a 1.80 mm corneal incision, using the IOL eyelets as anchoring point, is described. It was a retrospective review of 26 cases. The preoperative mean corrected distance visual acuity was 0.51 ± 0.21 logarithm of the minimum angle of resolution (logMAR). It improved significantly to 0.25 ± 0.27 logMAR (P < .01), 0.18 ± 0.16 logMAR (P < .01), and 0.17 ± 0.16 logMAR (P < .01) (at 1 month, 3 months, and 6 months postoperatively, respectively, repeated measures analysis of variance, P < .0001). No astigmatism increase of more than 0.75 diopters was recorded at any time point. In all 26 patients, the IOL was well centered and stable for the entire monitoring period. No complications were observed during follow-up. Scleral fixation of the foldable IOL through a 1.80 mm corneal incision provided excellent IOL stability during the 6-month follow-up of this study and might be an effective and safe surgical technique.
More Related Videos
Related Concept Videos
Angle Closure Glaucoma: Treatment
Glaucoma: Overview

