Improving the Diagnostic Accuracy of the PD-L1 Test with Image Analysis and Multiplex Hybridization

Matthew P Humphries1, Victoria Bingham1, Fatima Abdullahi Sidi1

  • 1Precision Medicine Centre of Excellence, The Patrick G Johnston Centre for Cancer Research, Queen's University, Belfast BT9 7BL, UK.

Cancers
|May 6, 2020
PubMed

Insights

Digital image analysis (DIA) and multiplex immunofluorescence enhance programmed cell death protein 1 (PD-1) ligand 1 (PD-L1) diagnostic accuracy in non-small cell lung cancer (NSCLC). These methods offer improved sensitivity and specificity for PD-L1 testing, aiding clinical decisions.

Area of Science:

  • Oncology
  • Immunotherapy
  • Diagnostic Pathology

Background:

  • Immune checkpoint inhibitors targeting the PD-1/PD-L1 axis have transformed non-small cell lung cancer (NSCLC) treatment.
  • Accurate PD-L1 expression assessment is crucial for treatment selection but remains complex and subjective.
  • Current diagnostic methods for PD-L1 require improvement in accuracy and reproducibility.

Purpose of the Study:

  • To evaluate the efficacy of digital image analysis (DIA) in improving PD-L1 diagnostic testing accuracy for NSCLC.
  • To assess the utility of multiplex immunofluorescence in complex PD-L1 assessment.
  • To compare the diagnostic performance of DIA and multiplex immunofluorescence against manual evaluation.

Main Methods:

  • A cohort of routine NSCLC patient samples, initially tested for PD-L1 (SP263) via immunohistochemistry (IHC), were analyzed using DIA.
  • Samples with varying assessment difficulty were further evaluated using multiplex immunofluorescence.
  • Sensitivity, specificity, and concordance rates were calculated for DIA and multiplex IHC compared to manual assessment.

Main Results:

  • DIA demonstrated significant concordance (R² = 0.8248) with manual PD-L1 assessment, showing 86.8% sensitivity and 91.4% specificity.
  • DIA scoring achieved 96.8% concordance with manual evaluation, indicating its reliability for case triage.
  • Multiplex immunofluorescence identified PD-L1+/CD68+ macrophages within tumor nests and offered higher sensitivity (97.8%) and specificity (91.8%) compared to chromogenic IHC.

Conclusions:

  • Digital image analysis is an accurate method for PD-L1 diagnostic assessment and efficient case triage in NSCLC.
  • Multiplex immunofluorescence enhances confidence in PD-L1 evaluation, particularly for challenging cases.
  • These advanced techniques can support clinical decision-making in NSCLC immunotherapy.