Introduction of standardized, cumulative quantitative measurement of blood loss into routine maternity care
Introduction:
Postpartum hemorrhage (PPH) is the leading cause of maternal morbidity in the UK. Visual estimation of blood loss is unreliable yet remains common practice. As part of a national quality improvement project to improve care during PPH, standardized, quantitative measurement of blood loss (QBL) for all deliveries was introduced into a tertiary obstetric unit in Cardiff, Wales.
Methods:
Retrospective analysis of 875 consecutive maternities between December 2017 and February 2018 was undertaken. Of these, 372 mothers had both pre- and post-partum hemoglobin (Hb) were recorded. Regression analyses were performed to investigate the relationship between change in Hb adjusted for red cell transfusion and QBL.
Results:
The correlation coefficient between QBL and adjusted change in Hb for all deliveries (n = 372) was 0.57. This corresponded to an estimated fall of adjusted change in Hb of 15.3 g/L (95% CI: 13.1, 17.6) per 1000 mL blood loss.
Discussion:
QBL has been shown to be reliable across all maternity settings, with reproducible results in theater and delivery rooms (on the obstetric unit and alongside midwifery-led unit). QBL is moderately correlated with adjusted change in Hb for all volumes of bleeding and gives clinicians more accurate knowledge of blood loss than visual estimation. This low-cost, low-fidelity intervention can influence the timely escalation of clinical care and therefore patient outcome.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Methods of Documentation V: CBE
In CBE, healthcare professionals establish predefined standards of practice that define what constitutes...