A comparison of the quality of image acquisition between two different sidestream dark field video-microscopes
Jonny Coppel1, Vassiliki Bountziouka2, Daniel Martin3,4
1University College London Centre for Altitude Space and Extreme Environment Medicine, UCLH NIHR Biomedical Research Centre, Institute of Sport Exercise and Health, 170 Tottenham Court Road, London, W1T 7HA, UK. jonny.coppel@gmail.com.
Abstract:
Sidestream dark field (SDF) imaging enables direct visualisation of the microvasculature from which quantification of key variables is possible. The new MicroScan USB3 (MS-U) video-microscope is a hand-held SDF device that has undergone significant technical upgrades from its predecessor, the MicroScan Analogue (MS-A). The MS-U claims superior quality of sublingual microcirculatory image acquisition over the MS-A, however, this has yet to be robustly confirmed. In this manuscript, we therefore compare the quality of image acquisition between these two devices. The microcirculation of healthy volunteers was visualised to generate thirty video images for each device. Two independent raters, blinded to the device type, graded the quality of the images according to the six different traits in the Microcirculation Image Quality Score (MIQS) system. Chi-squared tests and Kappa statistics were used to compare not only the distribution of scores between the devices, but also agreement between raters. MS-U showed superior image quality over MS-A in three of out six MIQS traits; MS-U had significantly more optimal images by illumination (MS-U 95% optimal images, MS-A 70% optimal images (p-value 0.003)), by focus (MS-U 70% optimal images, MS-A 35% optimal images (p-value 0.002)) and by pressure (MS-U 72.5% optimal images, MS-A 47.5% optimal images (p-value 0.02)). For each trait, there was at least 85% agreement between the raters, and all the scores for each trait were independent of the rater (all p-values > 0.05). These results show that the new MS-U provides a superior quality of sublingual microcirculatory image acquisition when compared to old MS-A.
More Related Videos
Related Concept Videos
Two-Dimensional Microscopy in Microbiology
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Three-Dimensional Microscopy in Microbiology