Related Experiment Video
Updated: Dec 22, 2025

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Surfactant Modified Graphite Paste Electrode as an Electrochemical Sensor for the Enhanced Voltammetric Detection of
Madikeri Manjunath Charithra1, Jamballi Gangadharappa Gowda Manjunatha1, Chenthattil Raril1
1Department of Chemistry, FMKMC College, Mangalore University Constituent College, Madikeri, Karnataka, India.
Abstract:
Estriol (ERL) is a type of hormone among the groups of estrogen hormone that was detected through the voltammetric technique by constructing an electrochemical sensor based on the octoxynol-9 modified graphite paste electrode (OXL-9MGPE). Using the strategy of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) with a bare graphite paste electrode (BGPE) immobilized with OXL-9, ERL electro-oxidation has been assessed in 0.2 M phosphate buffer solution (PBS) of pH 6.0. The fabricated electrode has substantial electrochemical sensing efficiency, and the ERL oxidation at the OXL-9MGPE was the irreversible process. The surface morphological characteristics of BGPE and OXL-9MGPE were differentiated with the help of field emission scanning electron microscopy (FE-SEM). The impact of various factors such as scan rate, pH, reproducibility, repeatability, and stability on the electro-oxidation of ERL was evaluated. Techniques of CV and DPV were utilized to determine ERL, dopamine (DAN), and uric acid (URA) simultaneously with the projected sensor. The peak current was varied with ERL concentration in the range from 4×10-5 to 1.2×10-4 M at OXL-9MGPE. From this, the detection limit 1.4×10 -6 M and limit of quantification (LOQ) 4.7×10-6 M have been attained. As a result, OXL-9MGPE was successfully achieved as an electrochemical detector for the electro analysis of ERL via the CV technique.
More Related Videos
07:34Gold Nanoparticle Modified Carbon Fiber Microelectrodes for Enhanced Neurochemical Detection
Published on: May 13, 2019
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
Related Concept Videos
Potentiometry: Membrane Electrodes
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Voltammetric Techniques: Linear-Scan (E vs Time)