Related Experiment Video
Updated: Dec 22, 2025

A Spin-Tip Enrichment Strategy for Simultaneous Analysis of N-Glycopeptides and Phosphopeptides from Human Pancreatic Tissues
Published on: May 4, 2022
Multiplexed Comparative Analysis of Intact Glycopeptides Using Electron-Transfer Dissociation and Synchronous
Hongbin Zhu1, Chen Qiu1, Connie M Gryniewicz-Ruzicka1
1Division of Pharmaceutical Analysis, Center for Drug Evaluation and Research, U.S. Food and Drug Administration, 645 South Newstead Avenue, St. Louis, Missouri 63110, United States.
Abstract:
A recently developed synchronous precursor selection (SPS) mass spectrometry to the third (MS3) protocol enables more accurate multiplexed quantification of proteins/peptides using tandem mass tags (TMT) through comparison of reporter ion intensities at the MS3 level. However, challenges still exist for TMT-based simultaneous quantification and identification of intact glycopeptides due to inefficient peptide backbone fragmentation when using collision-induced dissociation (CID). To overcome this limitation, here we report an improved SPS/ETD workflow for TMT-based intact glycopeptide quantification and identification. The SPS/ETD approach was implemented on an Orbitrap Tribrid mass spectrometer and begins with selection of a parent ion in the MS scan, followed by tandem mass spectrometry (MS2) fragmentation by CID in the ion trap. Following MS2 fragmentation, SPS enables simultaneous isolation of the top 10 MS2 fragment ions for further higher energy collisional dissociation (HCD) fragmentation with the resulting MS3 fragments detected in an Orbitrap analyzer. Here, in addition to the standard SPS workflow, an electron-transfer dissociation (ETD) MS2 was performed and analyzed in the ion trap. The resultant ETD and CID spectra were used for the identification of the intact glycopeptides, while the quantitative comparison of site-specific glycans was achieved utilizing TMT reporter ions from HCD MS3 spectra. For intact glycopeptides, through systematic optimization and evaluation using a glycoprotein interference model, the SPS/ETD approach was demonstrated to offer improved accuracy, precision, and sensitivity compared to traditional data-dependent MS2 quantification, while maintaining the glycopeptide identification capability. Finally, this workflow was applied for the site-specific quantitative comparison of the glycoforms for two therapeutic enzymes (Cerezyme and VPRIV) and their different lots. The results demonstrate that this workflow is suitable for TMT-based intact glycopeptide characterization of glycoproteins.
More Related Videos
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
10:59Glycomics-Guided Glycoproteomics Facilitates Comprehensive Profiling of the Glycoproteome in Complex Tumor Microenvironments
Published on: February 7, 2025
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry