Related Experiment Video
Updated: Dec 22, 2025

Blast Quantification Using Hopkinson Pressure Bars
Published on: July 5, 2016
Improving the Blast Resistance of Large Steel Gates-Numerical Study
Hasan Al-Rifaie1, Wojciech Sumelka1
1Institute of Structural Analysis, Poznan University of Technology, 60-965 Poznan, Poland.
Abstract:
Blast resistant gates/doors are essential for sensitive infrastructure, such as embassies, ministries, or parliaments. Lightweight gates equipped with 'energy absorbing systems' have better operational performance than the traditional costly and bulky design. Graded auxetic structures have not yet been used as potential passive damping systems in the supporting frame of blast resistant gates. Consequently, this study tries to test if a uniaxial graded auxetic damper (UGAD) proposed by the authors in a recent article, namely the development of a new shock absorbing UGAD, could maintain a 3000 × 4500 mm steel gate operable after high blast peak reflected overpressure of 6.6 MPa, from 100 kg TNT at 5 m stand-off distance. The blast-induced response of the gate was assessed, with and without the proposed UGAD, using Abaqus/Explicit solver. Results showed that the attachment of the proposed UGAD to the gate led to a dramatic decrease in permanent deformations (a critical factor for gate operability after a blast event). Hence, a lighter, more economical gate (with 50% reduction in mass) was required to satisfy the operability condition. In addition, 49% of peak reaction forces were diminished, that have a direct impact on the supporting frame. Moreover, the results revealed that, in the numerical model, 56% of the achieved plastic dissipation energy was from the UGADs, and 44% from the gate. The outcomes of this research may have a positive impact on other sectors beyond academia, such as industry, economy, and public safety.
Related Concept Videos
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Design Example: Distributing Reinforcements in Concrete Sections
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Design Example: Forces in Sluice Gate
Key variables in...
Steel Fastening Techniques
Rivets are cylindrical steel fasteners with a specially designed head. During application, rivets are heated until white-hot and then inserted through pre-drilled holes in the steel sections. A pneumatic hammer is used to shape the exposed end into a second head, securing the sections together.
Bolting is another...