Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Turbulent Supercritical Fluid Chromatography in Open-Tubular Columns for High-Throughput Separations
Michael R Galietti1, Valérie Peulon-Agasse2, Pascal Cardinael2
1Waters Corporation, Instrument/Core Research/Fundamental, 34 Maple Street, Milford, Massachusetts 01757, United States.
Abstract:
A method utilizing turbulent flow to perform ultrafast separations and screen chiral compounds in supercritical fluid chromatography (SFC) is described. Carbon dioxide at high flow rates (up to 4.0 mL/min) is delivered into gas chromatography (GC) open-tubular columns (OTC, 0.18 mm i.d., 20 m long, ∼0.2 μm stationary film thickness) to establish turbulent flow at Reynolds numbers (Re) as high as 9000. Postcolumn dispersion is eliminated by using a modified UV detector that takes measurements directly on column. Upon crossing the laminar-to-turbulent flow transition regime, a significant reduction in plate height is observed resulting in a nearly 3-fold increase in peak capacity from the laminar regime. This is explained by the massive reduction of the mass transfer resistance in the mobile phase due to a flatter flow profile and faster analyte dispersion across the open-tubular column (OTC) i.d.. Demonstrated in this work is a 9 s separation of four polycyclic aromatic hydrocarbons (PAHs) over a 2.2 s separation window using a poly(dimethylsiloxane-co-methylphenylsiloxane) coated OTC. Additionally, three chiral compounds and three chiral cyclodextrin-incorporated OTCs were evaluated at high temperatures (90-120 °C) and CO2 flow rates (3.3-3.7 mL/min) to demonstrate column stability and application of this method for rapid screening. Turbulent SFC provides a separation method for users desiring to achieve separation speeds above what is currently available with very high-pressure LC systems and do so without the resolution loss commonly observed at maximum allowable speed.
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process