Quantifying the impact from stroke during support with continuous flow ventricular assist devices: An STS INTERMACS
James K Kirklin1, David C Naftel1, Susan L Myers1
1Kirklin Institute for Research in Surgical Outcomes, University of Alabama, Birmingham, Alabama.
Summary
Strokes are a major complication after left ventricular assist device (LVAD) implantation, impacting survival. Disabling strokes significantly worsen long-term outcomes for heart failure patients.
Area of Science:
- Cardiology
- Medical Devices
- Neurology
Background:
- Adverse events, particularly strokes, are significant barriers to the wider application of continuous flow durable left ventricular assist devices (LVADs) in ambulatory advanced heart failure patients.
- Understanding stroke incidence and impact is crucial for improving patient outcomes.
Purpose of the Study:
- To analyze the incidence, risk factors, and mortality associated with stroke events following continuous flow LVAD implantation.
- To evaluate the impact of stroke severity on long-term survival.
Main Methods:
- Analysis of 10,285 continuous flow LVAD implantations from the Society of Thoracic Surgeons Interagency Registry for Mechanically Assisted Circulatory Support database (June 2014-June 2017) with follow-up through June 2018.
- Multivariable hazard function analysis and modulated renewal models were used to identify risk factors and mortality predictors.
Main Results:
- 16% of patients experienced at least one stroke, with equal ischemic and hemorrhagic rates. Stroke risk was 4% in the first month, 9% by 6 months, and 14% by 1 year.
- Early risk factors included centrifugal flow devices and concomitant cardiac surgery; long-term risk was associated with non-compliance.
- Ischemic stroke survival at 6 months was 70%, while hemorrhagic stroke survival was <50%. Disabling strokes significantly reduced 1- and 2-year survival.
Conclusions:
- Confirms a 20% stroke incidence within 2 years for axial and hybrid centrifugal flow pumps.
- Disabling strokes markedly increase 1- and 2-year mortality.
- Further research needs comprehensive Modified Rankin Scores and quality of life data to guide prevention and intervention strategies.
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
2.8K
Cardiac output (CO), the amount of blood the heart pumps per minute, is a parameter in cardiovascular physiology determined by stroke volume and heart rate. Stroke volume, the amount of blood pushed from one of the ventricles per heartbeat, is influenced by preload, afterload, and contractility.
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
2.8K
Cardiac Output and Stroke Volume
4.2K
Cardiac output (CO) is an integral aspect of human physiology, reflecting the heart's efficiency and responsiveness to the body's needs. It represents the volume of blood that the left or right ventricle ejects into the aorta or pulmonary trunk each minute. The CO is calculated by multiplying the heart rate (HR)—the number of heartbeats per minute—by the stroke volume (SV)—the amount of blood pumped out with each heartbeat.
In an average resting adult male, the typical cardiac...
In an average resting adult male, the typical cardiac...
4.2K
Regulation of Stroke Volume
4.5K
The regulation of stroke volume, which is the amount of blood the heart pumps out during each heartbeat, is critical for maintaining a healthy circulatory system. Stroke volume is influenced by three main factors: preload, contractility, and afterload.
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
4.5K