Related Experiment Video
Updated: Dec 22, 2025

Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
Short-Term Blood Flow Restriction Increases Power Output and Bar Velocity During the Bench Press
Michal Wilk1, Michal Krzysztofik1, Aleksandra Filip1
1Institute of Sport Sciences, Jerzy Kukuczka Academy of Physical Education in Katowice, Katowice, Poland.
Abstract:
Wilk, M, Krzysztofik, M, Filip, A, Zajac, A, Bogdanis, GC, and Lockie, RG. Short-term blood flow restriction increases power output and bar velocity during the bench press. J Strength Cond Res 36(8): 2082-2088, 2022-This study examined the effect of blood flow restriction (BFR) with 2 different types of cuffs on peak power output (PP), mean power output (MP), peak bar velocity (PV), and mean bar velocity (MV) in the bench press exercise (BP). Fourteen healthy strength-trained male athletes (age = 27.6 ± 3.5 years; body mass = 84.1 ± 8.0 kg; height = 175.8 ± 6.7 cm; BP 1 repetition maximum [RM] = 138.6 ± 17.8 kg) performed 3 different testing protocols as follows: without BFR (NO-BFR), BFR with a narrow cuff (BFR NARROW ), and BFR with a wide cuff (BFR WIDE ) in a randomized crossover design. During all sessions, subjects performed one set of 3 repetitions of the BP exercise using 70% 1RM. Cuff pressure was set to approximately 90% full arterial occlusion pressure of the upper limb at rest. Analyses of variance showed an increase in PP (by 21%, p < 0.01; effect size [ES] = 1.67), MP (by 16%, p < 0.01; ES = 0.93), PV (by 22%, p < 0.01; ES = 1.79), and MV (by 21%, p < 0.01; ES = 1.36) during BFR WIDE compared with NO-BFR and a significant increase in PP (by 15%, p < 0.01; ES = 1.07), MP (by 17%, p < 0.01; ES = 0.78), PV (by 18%, p < 0.01; ES = 1.65), and MV (by 13% p < 0.01; ES = 1.00) during BFR WIDE compared with BFR NARROW . There were no significant differences in any of the variable between NO-BFR and BFR NARROW . The results of the study indicate that short-term BFR training increases power output and bar velocity during the BP exercise. However, only BFR WIDE significantly influenced bar velocity and power output, which indicates that the width of the cuff is a critical factor determining acute exercise adaptation during BFR resistance training.
More Related Videos
Related Concept Videos
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Measurement of Blood Pressure
Blood Flow
Exercise and Muscle Performance
Endurance exercises
Endurance exercises involve running, swimming, or cycling, which require repetitive movements with low force output. When a person engages in endurance exercise, a few noticeable changes occur in their skeletal muscles. For instance, the number of capillaries...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.

