High-sensitivity cassette for reducing limit of detection for diesel particulate matter sampling
J D Noll1, A Bugarski2, S Vanderslice2
1U.S. Department of Health and Human Services, Public Health Service, Pittsburgh Research Laboratory, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, 626 Cochrans Mill Road, Pittsburgh, PA, 15236, USA. jnoll@cdc.gov.
Abstract:
NIOSH researchers designed a high-sensitivity (HS) cassette to improve the limit of detection of the National Institute for Occupational Safety and Health's (NIOSH) method 5040 and the Airtec near real-time diesel particulate matter (DPM) monitor. This was achieved by reducing the size of the diesel particulate matter deposition spot from 8.0 cm2 (NIOSH method 5040 mining samples) and 7.6 cm2 (Airtec samples) to 0.5 cm2. When compared with the standard cassette, the new high-sensitivity cassette improves the limit of detection of NIOSH method 5040 by approximately five times, and the differences between the elemental carbon results from the HS cassette and the standard three-piece cassette were within statistical error. The limit of detection for Airtec measurements improved by approximately 15 times, and the elemental carbon results with the HS cassette between the Airtec and NIOSH method 5040 were within statistical agreement. When used in the Airtec monitor, the high-sensitivity cassette showed promise for measuring short-duration spot checks of ambient concentrations but was limited when performing some long-term sampling due to the resultant loss of dynamic range. Only up to 7 μg of elemental carbon was collected onto the HS cassette before the increase in pump backpressure caused the flow fluctuations to exceed targeted values by unacceptable levels. The HS cassette shows promise for effective engineering evaluations of control technologies and strategies and near real-time diesel particulate matter measurements for a variety of occupations.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Tandem Mass Spectrometry
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...