Abstract:
The photolytic chlorination of n-alkanes in presence of sulfuryl chloride (SO2Cl2) was explored to produce new standard materials. Five mixtures of chlorinated tetradecanes were synthesized with chlorination degrees (mCl,EA) varying from 43.7% to 59.4% (m/m) based on elemental analysis. Chlorine-enhanced negative chemical ionization mass spectrometry (CE-NCI-MS) forcing the formation of chloride-adduct ions [M+Cl]- was applied to characterize these materials which all contained tetra-to deca-chlorinated paraffins. Deconvolution of respective mass spectra revealed the presence of chlorinated olefins (COs). CO levels were highest in materials, which were exposed longest. All synthesized materials also contained two classes of polar impurities, tentatively assigned as sulfite- and sulfate-diesters with molecular formulas of C14H28-xO3SClx (x = 1-4) and C14H28-xO4SClx (x = 3-6), respectively. MS data were in accordance with the proposed structures but further work is needed to deduce their constitutions. These compounds are thermolabile and were not detected with GC-MS methods. We could remove these sulfur-containing impurities from the CPs with normal-phase liquid chromatography. In conclusion, single-chain CP materials were synthesized via chlorination of n-alkanes with sulfuryl chloride, but these materials contained reactive side products which should be removed to gain non-reactive and stable CP materials suitable as standards and for fate and toxicity studies.
More Related Videos
13:34Generation of Scalable, Metallic High-Aspect Ratio Nanocomposites in a Biological Liquid Medium
Published on: July 8, 2015
11:37Protocol for the Solid-phase Synthesis of Oligomers of RNA Containing a 2'-O-thiophenylmethyl Modification and Characterization via Circular Dichroism
Published on: July 28, 2017
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...