Strategies in developing high-throughput liquid chromatography protocols for method qualification of pharmacopeial

Glenn A Kresge1, Sylvia Grosse2, Alexis Zimmer1

  • 1Department of Chemistry & Biochemistry, Rowan University, Glassboro, NJ, USA.

Related Concept Videos

High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
3.1K
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
1.2K
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
2.7K
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
172
Clinically Relevant Drug Product Specifications: Methods of Establishment01:29

Clinically Relevant Drug Product Specifications: Methods of Establishment

Product specifications define the acceptable quality of a pharmaceutical product by ensuring identity, purity, potency, and strength. These specifications serve as benchmarks during development, manufacturing, and post-approval quality control. Clinically relevant specifications are particularly important because they directly relate to a drug's safety and efficacy in clinical use.Dissolution studies are critical biopharmaceutic tools that link in vitro behavior to in vivo performance. They...
120
Data Validation01:15

Data Validation

Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
486