Rat Model of Right-Sided Cardiac Remodeling and Arrhythmia Using Pulmonary Artery Banding
Published on: August 30, 2024
Reducing Aortic Barotrauma and Vascular Extracellular Matrix Degradation by Pacemaker-Mediated QRS Widening
Murat Sezer1, Adem Atici1, Isa Coskun
1Department of Cardiology Capa Istanbul Faculty of Medicine Istanbul University Istanbul Turkey.
Abstract:
Background The extent of pressure-related damage might be related to acceleration rate of the applied pressure (peak dP/dt) in the vascular system. In this study, we sought to determine whether dP/dt applied to the aortic wall (aortic dP/dt) and in turn vascular extracellular matrix degradation can be mitigated via modulation of left ventricular (LV) contractility (LV dP/dt) by pacemaker-mediated desynchronization. Methods and Results First, in 34 patients, changes in aortic dP/dt values in 3 aortic segments in response to pacemaker-mediated stepwise QRS widening leading to gradual desynchronization of the LV contraction by means of steadily changed atrioventricular delay (AVD) with temporary dual-chamber pacing was examined before and after beta-blocker (15 mg IV metoprolol) administration. Second, serum matrix metalloproteinase-9 levels were measured in the 20 patients with permanent pacemaker while they were on sinus rhythm with normal QRS width and 3 weeks after wide QRS rhythm ensured by dual pacing, dual sensing, and dual response to sensing with short AVD. LV dP/dt substantially correlated with dP/dt measured in ascending (r=0.83), descending (r=0.89), and abdominal aorta (r=0.96). QRS width strongly correlated with dP/dt measured in ascending (r=-0.95), descending (r=-0.92), and abdominal (r=-0.96) aortic segments as well. In patients with permanent pacemaker, wide QRS rhythm led to a significant reduction in serum matrix metalloproteinase-9 levels (from 142.5±32.9 pg/mL to 87.5±32.4 pg/mL [P<0.001]) at the end of 3 weeks follow-up. Conclusions QRS prolongation by short AVD dual pacing, dual sensing, and dual response to sensing results in concomitant decreases in peak dP/dt values in the LV and in all aortic segments with or without background beta-blocker administration, which in turn led to a significant reduction in circulating matrix metalloproteinase-9 levels. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT03665558.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
08:56Sterile Pericarditis in Aachener Minipigs As a Model for Atrial Myopathy and Atrial Fibrillation
Published on: September 24, 2021