Thenar oxygen saturation (StO2) alterations during a spontaneous breathing trial predict extubation failure
Jaume Mesquida1,2, Guillem Gruartmoner3,4, Cristina Espinal3
1Critical Care Department, Parc Taulí Hospital Universitari. Institut d'Investigació i Innovació Parc Taulí (I3PT), Parc Taulí, 1, 08208, Sabadell, Spain. jmesquida@tauli.cat.
Background:
Weaning from mechanical ventilation (MV) is a cardiovascular stress test. Monitoring the regional oxygenation status has shown promising results in predicting the tolerance to spontaneously breathe in the process of weaning from MV. Our aim was to determine whether changes in skeletal muscle oxygen saturation (StO2) measured by near-infrared spectroscopy (NIRS) on the thenar eminence during a vascular occlusion test (VOT) can be used to predict extubation failure from mechanical ventilation.
Methods:
We prospectively studied 206 adult patients with acute respiratory failure receiving MV for at least 48 h from a 30-bed mixed ICU, who were deemed ready to wean by their physicians. Patients underwent a 30-min spontaneous breathing trial (SBT), and were extubated according to the local protocol. Continuous StO2 was measured non-invasively on the thenar eminence. A VOT was performed prior to and at 30 min of the SBT (SBT30). The rate of StO2 deoxygenation (DeO2), StO2 reoxygenation (ReO2) rate and StO2 hyperemic response to ischemia (HAUC) were calculated.
Results:
Thirty-six of the 206 patients (17%) failed their SBT. The remainder 170 patients (83%) were extubated. Twenty-three of these patients (13.5%) needed reinstitution of MV within 24 h. Reintubated patients displayed a lower HAUC at baseline, and higher relative changes in their StO2 deoxygenation rate between baseline and SBT30 (DeO2 Ratio). A logistic regression-derived StO2 score, combining baseline StO2, HAUC and DeO2 ratio, showed an AUC of 0.84 (95% CI 0.74-0.91) for prediction of extubation failure.
Conclusions:
Extubation failure was associated to baseline and dynamic StO2 alterations during the SBT. Monitoring StO2-derived parameters might be useful in predicting extubation outcome.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-IV