Related Experiment Video
Updated: Dec 21, 2025

Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
Determination of radon exhalation rates from soil around buildings in Lagos environments using passive measurement
Oluwasayo Peter Abodunrin1, Margaret Kofoworola Akinloye2
11Department of Physical Sciences, Bells University of Technology, Ota, PMB 1015 Nigeria.
Purpose:
In this study, measurements of radon concentrations and estimation of exhalation rates were carried out in soil around buildings within Lagos State in order to determine the contribution to indoor radon concentrations from the soil, and determine the influence of soil moisture on the exhalation rates.
Methods:
Fifty-four samples were collected randomly with 27 measured as wet samples and 27 dried before measurements so as to account for the moisture content. Passive measurement method, using cover cup technique with solid state nuclear track detectors, CR-39, was employed.
Results:
The results showed weak correlations between the concentrations of radon emanated from the soil samples and the indoor radon concentrations. The results obtained suggested lower concentrations of radon emanated from wet soil than dry soil indicating the influence of moisture. The results further indicate that the highest and lowest values as well as the highest mean for both wet and dry soil samples were obtained from the same environment, suggesting that the soil in that environment are of anomalous petrophysical property.
Conclusion:
Concentrations of radon emanated from dry soil are higher than in wet soil, suggesting that the presence of moisture may results in reduction of radon concentrations in soil samples. The result of the surface exhalation rates and the mass exhalation rates are in congruent with results obtained for the concentrations of radon emanated from wet and dry soil samples.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
08:05Measurement of the Potential Rates of Dissimilatory Nitrate Reduction to Ammonium Based on 14NH4+/15NH4+ Analyses via Sequential Conversion to N2O
Published on: October 7, 2020
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: