Abstract:
Full-scan, data-dependent acquisition (DDA), and data-independent acquisition (DIA) are the three common data acquisition modes in high resolution mass spectrometry-based untargeted metabolomics. It is an important yet underrated research topic on which acquisition mode is more suitable for a given untargeted metabolomics application. In this work, we compared the three data acquisition techniques using a standard mixture of 134 endogenous metabolites and a human urine sample. Both hydrophilic interaction and reversed-phase liquid chromatographic separation along with positive and negative ionization modes were tested. Both the standard mixture and urine sample generated consistent results. Full-scan mode is able to capture the largest number of metabolic features, followed by DIA and DDA (53.7% and 64.8% respective features fewer on average in urine than full-scan). Comparing the MS2 spectra in DIA and DDA, spectra quality is higher in DDA with average dot product score 83.1% higher than DIA in Urine(H), and the number of MS2 spectra (spectra quantity) is larger in DIA (on average 97.8% more than DDA in urine). Moreover, a comparison of relative standard deviation distribution between modes shows consistency in the quantitative precision, with the exception of DDA showing a minor disadvantage (on average 19.8% and 26.8% fewer features in urine with RSD < 5% than full-scan and DIA). In terms of data preprocessing convenience, full-scan and DDA data can be processed by well-established software. In contrast, several bioinformatic issues remain to be addressed in processing DIA data and the development of more effective computational programs is highly demanded.
Related Concept Videos
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors