Measurement of dilation pulses using a pulse-dilation framing camera
Optics Express
|May 15, 2020
Summary
A pulse-dilation framing camera (PFC) can accurately measure the waveform and time history of dilation pulses. This research validates the PFC
Area of Science:
- * Physics
- * Optics
- * Instrumentation
Background:
- * Framing cameras are essential tools in scientific research.
- * Understanding pulse dynamics is critical in various optical applications.
- * Existing methods for measuring pulse characteristics may have limitations.
Purpose of the Study:
- * To introduce the pulse-dilation framing camera (PFC) and its operational principles.
- * To analyze the influence of dilation pulses on camera exposure time.
- * To theoretically and experimentally verify the PFC's capability in measuring dilation pulse waveforms and time histories.
Main Methods:
- * Theoretical simulation of dilation pulse potential using known PFC dilation factors.
- * Experimental measurement of PFC exposure time and dilation factors using fiber optic bundles.
- * Data acquisition through multiple measurements to achieve waveform and time history.
Main Results:
- * Theoretical simulation showed a potential deviation of approximately 3.2% at the end of the dilation pulse.
- * Experimental measurements yielded a potential deviation of approximately 6.3% at the end of the dilation pulse.
- * Experimental results demonstrated consistency with theoretical analysis, confirming PFC feasibility.
Conclusions:
- * The pulse-dilation framing camera (PFC) is a feasible tool for measuring dilation pulse waveforms and time histories.
- * Minor deviations between theoretical and experimental results were observed but do not impede feasibility.
- * This research may inspire novel applications for framing camera technology.
More Related Videos
Related Concept Videos
Special considerations while measuring pulse
832
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
832
Pulse
1.8K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
1.8K
Equipments Used To Measure Blood Pressure
2.9K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.9K