Related Experiment Video
Updated: Dec 21, 2025

Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
On-orbit radiometric calibration of the optical sensors on-board SuperView-1 satellite using three independent
Abstract:
On-orbit radiometric calibration of the optical sensors on-board SuperView-1 satellites is the foundation for further quantitative applications. A field calibration campaign was orchestrated to radiometrically calibrate the SuperView-1 optical sensors at the Baotou calibration site in China during September 2018. Based on the collected datasets, three independent methods (reflectance-based, radiance-based, and cross-calibration) were used to determine the radiometric calibration coefficients of the SuperView-1 optical sensors with multiple permanent artificial calibration targets. Comparisons of the desert top-of-atmosphere radiance calculated based on the coefficients determined with independent methods were analyzed. Comparison results show that the minimum and maximum relative differences of the radiometrically-calibrated desert TOA radiance between the reflectance-based and radiance-based methods are 1.26% and 4.23% for SV0102 and SV0104, respectively. While, the minimum and maximum relative differences of the radiometrically-calibrated desert TOA radiance between the reflectance-based and radiance-based methods are 0.82% and 6.83% for SV0101 and SV0103, respectively. The reasonably good agreement of the radiometrically calibrated coefficients of the SuperView-1 on-board sensors between these independent methods is encouraging. An uncertainty analysis was also discussed, and the results suggest that the overall uncertainties of the predicted TOA radiance are less than 4.5%, 4.0%, and 5.15% for the reflectance-based, radiance-based, and cross-calibration methods, respectively.
More Related Videos
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
06:27Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
Published on: May 29, 2019
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Types of Global Positioning System Surveys
Uncertainty in Measurement: Reading Instruments
Design Example: Identifying the Locations of Monuments in the Field Using Global Positioning System Device
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...