Related Experiment Video For Clostridium perfringens
Updated: Dec 21, 2025

Enrichment and Detection of Clostridium perfringens Toxinotypes in Retail Food Samples
Published on: October 18, 2019
Diagnostic Accuracy of Nucleic Acid Amplification-Based Assays for Clostridium perfringens-Associated Diseases: a
Ke Chen1, Sarfraz Ahmed2, Yun-Juan Sheng3
1Anatomy and Structural Biology Graduate Program, Department of Anatomy, Faculty of Science, Mahidol University, Bangkok, Thailand.
Abstract:
Timely and accurate methods for detecting Clostridium perfringens-associated diseases (CPAD) are crucial to improve patient care. A number of studies have evaluated the accuracy of nucleic acid amplification tests (NAAT) in detecting CPAD, but decisive results about their effectiveness have not been reported. We conducted a meta-analysis to evaluate the diagnostic performance of NAAT for detecting C. perfringens in clinical diarrheal samples. Five databases including PubMed, Embase, Scopus, Web of Science, and the Cochrane library were systematically probed for studies published before 6 December 2019. From 2,632 citations, we identified five eligible studies comprising 817 samples. Three studies (n = 695 samples) compared NAAT with a microbiological culture while the other three studies (n = 322 samples) compared NAAT with an immunoassay. NAAT revealed higher diagnostic accuracy against immunoassay (sensitivity, 0.53 [95% confidence interval [CI], 0.35 to 0.7]; specificity, 0.97 [95% CI, 0.95 to 0.99]; positive likelihood ratio [PLR], 23.2 [95% CI, 3.49 to 153.98]; negative likelihood ratio [NLR], 0.25 [95% CI, 0 to 245.28]; diagnostic odds ratio [DOR], 74.11 [95% CI, 2.11 to 2,593.7]) than microbiological culture (sensitivity, 0.31 [95% CI, 0.22 to 0.41]; specificity, 0.95 [95% CI, 0.93 to 0.97]; PLR, 11.56 [95% CI, 3.87 to 34.6]; NLR, 0.57 [95% CI, 0.27 to 1.21]; DOR, 18.1 [95% CI, 4.83 to 67.8]). NAAT pooled specificity was consistently ≥95% against that of applied reference standards. A meta-regression and subgroup analysis of sample condition, gene target, study design, and reference standards could not explain the heterogeneity (P > 0.05) in the diagnostic efficiency. The analysis has demonstrated that the diagnostic accuracy of NAAT is relatively insufficient to replace traditional reference standards as a single diagnostic test. NAAT can be applied in combination with microbiological culture because of the advantage of time to result and in scenarios where traditional tests are not feasible. Further investigations in this direction with larger sample sizes are still warranted to support our findings.
More Related Videos
09:12A Protein Microarray Assay for Serological Determination of Antigen-specific Antibody Responses Following Clostridium difficile Infection
Published on: June 15, 2018
07:59Rapid and Specific Detection of Acinetobacter baumannii Infections Using a Recombinase Polymerase Amplification/Cas12a-based System
Published on: April 25, 2025