Related Experiment Video
Updated: Dec 21, 2025

Knee Arthrocentesis in Adults
Published on: February 25, 2022
Comparison of Lutetium-177 tin colloid and Rhenium-188 tin colloid radiosynovectomy in chronic knee arthritis
Shamim Ahmed Shamim1, Geetanjali Arora1, Pragati Jha1
1Departments of Nuclear Medicine.
Objective:
To assess the role of Lutetium-177(Lu-177) tin colloid for radiosynovectomy and compare it with Rhenium-188 (Re-188) tin colloid radiosynovectomy for alleviation of pain in patients with chronic inflammatory arthritis of knee.
Methods:
Patients of chronic inflammatory arthritis of the knee underwent pretherapeutic evaluation in a form of knee ultrasonogram, bone scan and clinical evaluation. Fifty-seven recruited patients were allocated at random to receive either intraarticular injections of Lu-177 tin colloid or Re-188 tin colloid. Eventually, 27 patients received Re-188 tin colloid and 30 patients received Lu-177 tin colloid. The joint was then immobilized for 2 days. Response evaluation was done using knee ultrasound, bone scan and clinical findings.
Result:
Of 30, 20 patients responded to radiosynovectomy in the Lu-177 tin colloid group compared to 21/27 patients in the Re-188 tin colloid group.
Conclusion:
Lu-177 tin colloid is an effective alternative to Re-188 tin colloid for radiosynovectomy in patients with chronic inflammatory knee arthritis.