Risk factors for subsidence of modular fluted tapered stem implanted by using transfemoral Wagner approach during revision hip arthroplasty
Related Experiment Video
Updated: Dec 21, 2025

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Dino Bobovec1, Ivan Bohaček2, Josip Juras3
1Department of Surgery, University Hospital Centre Zagreb, Zagreb, Croatia.
Purpose:
To determine clinical and radiographic risk factors for the vertical subsidence of modular fluted tapered stems implanted using the transfemoral Wagner approach in a cohort of revision hip arthroplasties.
Methods:
A retrospective review of a single-centre surgical registry was performed. Patients who underwent a revision total hip arthroplasty, in which the uncemented modular fluted tapered stem (REVISION Hip/Anca-Ti6Al4V, LimaCorporate, Udine, Italy) was implanted using the transfemoral Wagner approach, were identified. Patient's demographic data, clinical and radiographic outcomes and post-operative complications were assessed. As a significant subsidence, a 5-mm cut-off was chosen.
Results:
We identified 278 revision hip arthroplasties with a mean follow-up of 35 months. The median of subsidence in the group of 5 mm and less was 2 mm, and 17 mm in the group of subsidence of 5 mm and more. A negative correlation was found between the stem subsidence and the length of good contact between the medial and lateral cortical bone and the stem (medial, - 0.248; P < 0.001, lateral, 0.284; P < 0.001). For 200 mm stems, the percentage of good contact between femoral parts of stem and bone on medial side was 40.5% (81.0 mm) for patients with subsidence of five or less mm, and 30% (60.0 mm) for lateral side. For 140 mm stems, the percentage was 52.86% (74.0 mm) for medial side and 40.36% (56.5 mm) for lateral side. A neck length was shown to correlate significantly with the stem subsidence (P = 0.004).
Conclusion:
It is crucial to provide good contact between the bilateral cortical bone and stem, and, if possible, to select implant constructs with shorter femoral necks, in order to reduce subsidence and to ensure longer implant survivorship.
More Related Videos
07:45The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
09:51The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022