Related Experiment Video
Updated: Dec 21, 2025

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
The Influence of Implant Inclination on Retention and Peri-implant Stresses of Stud-Retained Implant Overdentures
Purpose:
The purpose of this study was to evaluate the influence of implant inclination on retention and peri-implant stresses of stud-retained implant overdentures during axial and nonaxial dislodgments.
Materials And Methods:
Mandibular acrylic models (n = 4) received two implants in the canine areas with 0-, 5-, 10-, and 20-degree lingual inclinations. Dentures were attached to the implants with stud connectors. Four strain gauges were bonded at buccal, lingual, mesial, and distal surfaces of each implant to monitor strains around implants. Retention values (Newton) and peri-implant stresses (microstrains, μs) were recorded during axial (vertical) and nonaxial (anterior, posterior, and lateral) dislodging. A general linear model was used to compare retention forces and implant stresses between implant inclinations and dislodging direction. In addition, a linear regression model was used to test correlation of implant stresses with confounding factors.
Results:
The highest retention and implant stresses were noted with 0 degrees, followed by 5 and 10 degrees (without difference), and the lowest values were noted with 20 degrees. Anterior dislodging was associated with the highest retention and implant stresses, followed by vertical dislodging, then lateral dislodging, and posterior dislodging. Peri-implant stresses significantly correlated with dislodging direction and retention forces. Every 1 N of increase in retention forces causes 19.17 μs increase in implant stresses. Anterior dislodging was associated with the highest predicted stress values (846.0 μs), and the lowest stress values (143.41 μs) were associated with posterior dislodging.
Conclusion:
Retention forces and peri-implant stresses decreased as lingual implant inclination increased during axial and nonaxial dislodging of stud-retained implant overdentures. Peri-implant stresses were significantly correlated with dislodging direction and retentive forces.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:32Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
Related Concept Videos
Residual Stresses in Circular Shafts
Normal Strain under Axial Loading