POCIS Calibration for Organic Compound Sampling in Small Headwater Streams
Kees Booij1, Sunmao Chen2, Jennifer R Trask3
1Passive Sampling of Organic Compounds (PaSOC), Kimswerd, The Netherlands.
Environmental Toxicology and Chemistry
|May 15, 2020
Summary
The polar organic chemical integrative sampler (POCIS) method accurately measured atrazine sampling rates in streams. A consistent rate of 148 mL/d was observed across multiple sites and years.
Area of Science:
- Environmental Chemistry
- Water Quality Monitoring
- Environmental Toxicology
Background:
- Atrazine is a widely used herbicide, and its presence in headwater streams necessitates accurate monitoring.
- The polar organic chemical integrative sampler (POCIS) is a passive sampling technique used for assessing contaminant levels in aquatic environments.
Purpose of the Study:
- To determine field-based atrazine sampling rates (Rs) using the POCIS method in headwater streams.
- To evaluate the performance of a mechanistic model for predicting POCIS sampling rates.
- To assess factors influencing POCIS sampling efficiency, including flow velocity and temperature.
Main Methods:
- Conducted field sampling over three years in nine headwater streams, with multiple exposure periods per site per year.
- Measured atrazine concentrations using the POCIS method and analyzed sampling rates (Rs).
- Assessed POCIS performance by measuring alabaster dissolution rates and developed a mechanistic model incorporating flow and temperature effects.
Main Results:
- Field-based atrazine sampling rates (Rs) were consistently measured at approximately 148 mL/d, with a standard deviation of 0.17 log units (factor 1.5).
- POCIS canisters were found to reduce mass transfer coefficients by a factor of two.
- A mechanistic model provided a fair estimate of the effective exchange surface area (12.5 ± 0.8 cm²), though its accuracy was limited at low flow velocities (<1 cm/s).
Conclusions:
- The atrazine sampling rate of 148 mL/d using POCIS provided consistent results across nine headwater streams over three years.
- Sorbent distribution and chemical analysis were identified as minor sources of error in the sampling process.
- The study confirmed the reliability of the POCIS method for long-term, low-level monitoring of atrazine in headwater streams.