A Method to Assess the Relevance of Nanomaterial Dissolution During Reactivity Testing
Willie J G M Peijnenburg1,2, Emmanuel Ruggiero3, Matthew Boyles4
1National Institute of Public Health and the Environment (RIVM), Center for Safety of Substances and Products, 3721 MA Bilthoven, The Netherlands.
Abstract:
The reactivity of particle surfaces can be used as a criterion to group nanoforms (NFs) based on similar potential hazard. Since NFs may partially or completely dissolve over the duration of the assays, with the ions themselves inducing a response, reactivity assays commonly measure the additive reactivity of the particles and ions combined. Here, we determine the concentration of ions released over the course of particle testing, and determine the relative contributions of the released ions to the total reactivity measured. We differentiate three classes of reactivity, defined as being A) dominated by particles, B) additive of particles and ions, or C) dominated by ions. We provide examples for each class by analyzing the NF reactivity of Fe2O3, ZnO, CuO, Ag using the ferric reduction ability of serum (FRAS) assay. Furthermore, another two reactivity tests were performed: Dichlorodihydrofluorescin diacetate (DCFH2‑DA) assay and electron paramagnetic resonance (EPR) spectroscopy. We compare assays and demonstrate that the dose‑response may be almost entirely assigned to ions in one assay (CuO in DCFH2‑DA), but to particles in others (CuO in EPR and FRAS). When considering this data, we conclude that one cannot specify the contribution of ions to NF toxicity for a certain NF, but only for a certain NF in a specific assay, medium and dose. The extent of dissolution depends on the buffer used, particle concentration applied, and duration of exposure. This culminates in the DCFH2‑DA, EPR, FRAS assays being performed under different ion‑to‑particle ratios, and differing in their sensitivity towards reactions induced by either ions or particles. If applied for grouping, read‑across, or other concepts based on the similarity of partially soluble NFs, results on reactivity should only be compared if measured by the same assay, incubation time, and dose range.
Related Concept Videos
Drug Dissolution: Requirements and Profile Comparison
Factors Affecting Dissolution: Particle Size and Effective Surface Area
In Vitro Drug Dissolution: Alternative Methods
In Vitro Drug Dissolution: Compendial Testing Models II
In Vitro Drug Release Testing: Overview, Development and Validation
In Vitro Drug Dissolution: Compendial Testing Models I