Related Experiment Video
Updated: Dec 21, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Tracheal tube size in adults undergoing elective surgery - a narrative review
1Department of Anaesthesiology, Vancouver General Hospital, Vancouver, BC, Canada.
Abstract:
Tracheal tubes are routinely used in adults undergoing elective surgery. The size of the tracheal tube, defined by its internal diameter, is often generically selected according to sex, with 7-7.5 mm and 8-8.5 mm tubes recommended in women and men, respectively. Tracheal diameter in adults is highly variable, being narrowest at the subglottis, and is affected by height and sex. The outer diameter of routinely used tracheal tubes may exceed these dimensions, traumatise the airway and increase the risk of postoperative sore throat and hoarseness. These complications disproportionately affect women and may be mitigated by using smaller tracheal tubes (6-6.5 mm). Patient safety concerns about using small tracheal tubes are based on critical care populations undergoing prolonged periods of tracheal intubation and not patients undergoing elective surgery. The internal diameter of the tube corresponds to its clinical utility. Tracheal tubes as small as 6.0 mm will accommodate routinely used intubation aids, suction devices and slim-line fibreoptic bronchoscopes. Positive pressure ventilation may be performed without increasing the risk of ventilator-induced lung injury or air trapping, even when high minute volumes are required. There is also no demonstrable increased risk of aspiration or cuff pressure damage when using smaller tracheal tubes. Small tracheal tubes may not be safe in all patients, such as those with high secretion loads and airflow limitation. A balanced view of risks and benefits should be taken appropriate to the clinical context, to select the smallest tracheal tube that permits safe peri-operative management.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: