Related Experiment Video
Updated: Dec 21, 2025

Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
Published on: June 3, 2018
ZnO-reduced graphene oxide composite based photoelectrochemical aptasensor for sensitive Cd(II) detection with
Yanyan Niu1, Hui Xie1, Guiling Luo1
1Key Laboratory of Water Pollution Treatment and Resource Reuse of Hainan Province, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, 571158, PR China.
Abstract:
In this paper a photoelectrochemical (PEC) aptasensor based on specific recognition with conformational changed after the target Cd(II) identification was fabricated. A ZnO and reduced graphene oxide (ZnO-rGO) nanocomposite with enhanced PEC activity was designed as photoactive material. After the further incorporation of gold nanoparticles (AuNPs) with ZnO-rGO nanocomposite, the enhanced photocurrent signal could be detected owing to the localized surface plasmon resonance and good conductivity of AuNPs. In addition, AuNPs were used as anchors for immobilization of -SH modified aptamer S1. After that aptamer S2 was paired with S1 sequence to form complementary double stranded DNA (dsDNA) on the electrode surface. Methylene blue (MB) was acted as sensitizer and assembled in dsDNA structure to amplify photocurrent response. When Cd(II) was bound to the aptamer presented on the sensing interface, S2 specifically recognized and captured Cd(II), which resulted in the unwinding of dsDNA structure and the separation of MB molecules from the electrode surface with photocurrent response decreased. The photocurrent was detected by a double-working-electrode system, which used the modified electrode as the first working electrode and glassy carbon electrode (GCE) as the second working electrode. Dopamine (DA) was added to the electrolyte and acted as the electron donor, which could be oxidized on the modified electrode and reduced on the GCE to form a cyclic reaction, leading to the enhanced photocurrent response with improved photocurrent stability. This MB sensitized PEC aptasensor exhibited a high sensitivity with a detection limit of 1.8 × 10-12 mol/L (3σ). Thus, a highly sensitive aptasensor with double-working-electrode detection method for Cd(II) determination were established and further applied to the water samples analysis.
More Related Videos
08:57Scalable Syntheses of Graphene Oxide and Reduced Graphene Oxide using Cascade Design Oxidation and Highly Basic Reduction Reactions
Published on: July 3, 2025
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019