Background:
Acute respiratory distress syndrome (ARDS) is associated with high mortality despite advances in the field of critical care, including growing implementation of veno-venous extracorporeal membrane oxygenation (V-V ECMO) support. The primary aim of this study was to present complications during transport on V-V ECMO support from regional hospitals to a tertiary center. The secondary goal was to identify initial laboratory and demographic data differentiating survivors and non-survivors.
Methods:
This was a retrospective, single-center, case-series study. We extracted data from the hospital's ECMO database from March 2016 to June 2019. Patients' diagnosis at admission, baseline demographics, the Sequential Organ Failure Assessment (SOFA) and the Respiratory ECMO Survival Prediction (RESP) scoring systems, laboratory parameters at admission, duration of ECMO therapy and mechanical ventilation time, and the patient survival rate until the ICU discharge were analyzed.
Results:
We assessed 31 patients retrieved from regional intensive care units. All analyzed transports on V-V ECMO were performed by an ambulance and median distance and transport time were 100 kilometers and 70 minutes, respectively. Minor complications during the transport were reported in 10 cases (32.25%). The mean V-V ECMO support time was 6.56 days and survival rate until the patient discharge was 64.51%. We found higher body mass index (33.5 vs. 26.5, P = 0.00251) and lower serum lactate level (1.25 vs. 1.6, P = 0.0058) at V-V ECMO initiation to correlate with higher survival rates.
Conclusions:
The transport of patients on V-V ECMO support appears to be safe and feasible. Further studies are needed to identify the specific clinical conditions which might affect the final outcomes.
More Related Videos
09:54Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-IV
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Acute Respiratory Failure-III