Multibeam absolute stimulated Raman scattering and two-plasmon decay
R K Follett1, J G Shaw1, J F Myatt2
1Laboratory for Laser Energetics, University of Rochester, 250 East River Road, Rochester New York 14623, USA.
Physical Review. E
|May 20, 2020
Summary
Multibeam effects significantly impact stimulated Raman scattering (SRS) and two-plasmon decay (TPD) instabilities in fusion plasmas. Two-plasmon decay shows stronger multibeam coupling than SRS, explaining observed experimental regimes.
Area of Science:
- Plasma Physics
- Fusion Energy
- Laser-Plasma Interactions
Background:
- Inertial confinement fusion (ICF) relies on understanding laser-plasma instabilities.
- Stimulated Raman scattering (SRS) and two-plasmon decay (TPD) are key instabilities affecting ICF performance.
- Previous studies often focused on single-beam interactions, neglecting multibeam effects.
Purpose of the Study:
- To calculate three-dimensional absolute instability thresholds for SRS and TPD.
- To compare multibeam coupling efficiencies for SRS and TPD.
- To explain observed experimental regimes on OMEGA and NIF based on instability behavior.
Main Methods:
- Three-dimensional numerical calculations of instability thresholds.
- Analysis of plasma conditions relevant to OMEGA and NIF direct-drive ICF experiments.
- Comparison of single-beam and multibeam instability thresholds.
Main Results:
- Multibeam effects are significant for both SRS and TPD.
- SRS exhibits less efficient multibeam coupling compared to TPD.
- The minimum instability threshold for NIF parameters occurs for SRS near quarter-critical density.
Conclusions:
- The findings align with experimental observations of TPD-dominated regimes on OMEGA and SRS-dominated regimes on NIF.
- Despite lower single-beam SRS thresholds, multibeam coupling influences the dominant instability.
- Understanding these multibeam effects is crucial for optimizing ICF performance.
Related Concept Videos
Raman Spectroscopy: Overview
1.2K
The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
1.2K
Raman Spectroscopy Instrumentation: Overview
885
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
885
Super-resolution Fluorescence Microscopy
12.1K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.1K