Three-Dimensional Ultrasonic Needle Tip Tracking with a Fiber-Optic Ultrasound Receiver
Published on: August 21, 2018
Characterization of an Ultrasonic Local Positioning System for 3D Measurements
Khaoula Mannay1,2, Jesús Ureña2, Álvaro Hernández2
1EμE Lab, Faculty of Sciences of Monastir, National Engineer School of Tunis, University of Tunis EI Manar, B.P. 37, Le Belvédère, Tunis 1002, Tunisia.
Abstract:
Indoor location and positioning systems (ILPS) are used to locate and track people, as well as mobile and/or connected targets, such as robots or smartphones, not only inside buildings with a lack of global navigation satellite systems (GNSS) signals but also in constrained outdoor situations with reduced coverage. Indoor positioning applications and their interest are growing in certain environments, such as commercial centers, airports, hospitals or factories. Several sensory technologies have already been applied to indoor positioning systems, where ultrasounds are a common solution due to its low cost and simplicity. This work proposes a 3D ultrasonic local positioning system (ULPS), based on a set of three asynchronous ultrasonic beacon units, capable of transmitting coded signals independently, and on a 3D mobile receiver prototype. The proposal is based on the aforementioned beacon unit, which consists of five ultrasonic transmitters oriented towards the same coverage area and has already been proven in 2D positioning by applying hyperbolic trilateration. Since there are three beacon units available, the final position is obtained by merging the partial results from each unit, implementing a minimum likelihood estimation (MLE) fusion algorithm. The approach has been characterized, and experimentally verified, trying to maximize the coverage zone, at least for typical sizes in most common public rooms and halls. The proposal has achieved a positioning accuracy below decimeters for 90% of the cases in the zone where the three ultrasonic beacon units are available, whereas these accuracies can degrade above decimeters according to whether the coverage from one or more beacon units is missing. The experimental workspace covers a large volume, where tests have been carried out at points placed in two different horizontal planes.
More Related Videos
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
08:523D Ultrasound Imaging: Fast and Cost-effective Morphometry of Musculoskeletal Tissue
Published on: November 27, 2017
Related Concept Videos
Types of Global Positioning System Surveys
Electronic Distance Measuring Instruments