Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Comparison and Combination of Single-Lead ECG and Photoplethysmography Algorithms for Wearable-Based Atrial
Markus R Mutke1,2, Noe Brasier1,3, Christina Raichle4
1Chief Medical Information Officer - Office, University Hospital Basel, Basel, Switzerland.
Abstract:
Atrial fibrillation (AF), the most common cardiac arrhythmia, can be detected by smartphones and smartwatches. Single-lead ECGs (iECGs) and photoplethysmography (PPG) sensors provide the opportunity for a broad, simple, and easily repeatable cardiac rhythm analysis. To reduce unnecessary medical follow-up testing due to false positive results, our aim was to find a screening approach applicable on smart devices with a focus on high specificity. We used PPG measurements from smartphones and smartwatches and iECG data from two previous validation trials. Two AF detection algorithms (A and B) were applied on the iECG dataset and compared directly. Further, we used 1-min PPG measurements as a first-pass filter for arrhythmia detection and simulated a sequential testing: Once an arrhythmia was detected in the PPG, the iECG counterpart of the patient was analyzed by algorithm A, B, or A + B combined although algorithm B was primarily designed for PPG analysis. The iECGs from 1,288 participants were analyzed. Algorithm A did not show a diagnosis in 16.1%. In the remaining, sensitivity and specificity were 99.6%, and 97.4% respectively. Accuracy was 98.5%, and correct classification rate (CCR) was 82.7%. Algorithm B always differentiated between normal and arrhythmic and reached an overall sensitivity of 95.4%, a specificity of 91.6%, and an accuracy and CCR of 93.3%. Sequential testing by combining both algorithms into a three-phase test (Test positive PPG, then iECG analysis by A and B combined) resulted in a 100% specificity. Algorithm B performed strongly in PPG analysis as well as iECG analysis. PPG signals and consecutive iECG combined when an arrhythmia was detected by PPG resulted in a specificity that was higher than 99%. The analysis allows a direct comparison of iECG algorithms without possible dilution by different measurement procedures or recording-devices. We improved specificity in AF-screening approaches with wearables by simulating a novel approach. Results rely on signal quality.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Holter Monitor: 24-Hour Monitoring