Related Experiment Video
Updated: Dec 21, 2025

Probe-based Confocal Laser Endomicroscopy of the Urinary Tract: The Technique
Published on: January 10, 2013
A Near-Infrared Fluorescent Probe Coated with β-Cyclodextrin Molecules for Real-Time Imaging-Guided Intraoperative
1Graduate School of Bioresources, Mie University, Mie 514-8507, Japan.
Although iatrogenic ureteral injury and its lack of recognition due to ureteral invisibility are serious incidents in open and laparoscopic abdominal surgeries, there are currently no safe and effective methods for intraoperative ureteral identification (IUI) and diagnosis (IUD). In this study, I designed and chemically synthesized a near-infrared fluorescence (NIRF) imaging probe (CD-NIR-1) and evaluated its clearance and ability for IUI and IUD in animal models. CD-NIR-1 demonstrated high specificity and ultrarapid clearance by rat kidneys to the urinary bladder following intravenous administration of a single dose (25 nmol/kg of body weight), with 96% of the dose ultimately excreted at the first urination with no chemical modification. Furthermore, urine containing CD-NIR-1 in ureters showed strong NIRF, thereby enabling IUI and IUD via NIRF imaging. These results demonstrated the efficacy of CD-NIR-1 for clinical use.
Although iatrogenic ureteral injury and its lack of recognition due to ureteral invisibility are serious incidents in open and laparoscopic abdominal surgeries, there are currently no safe and effective methods for intraoperative ureteral identification (IUI) and diagnosis (IUD). In this study, I designed and chemically synthesized a near-infrared fluorescence (NIRF) imaging probe (CD-NIR-1) and evaluated its clearance and ability for IUI and IUD in animal models. CD-NIR-1 demonstrated high specificity and ultrarapid clearance by rat kidneys to the urinary bladder following intravenous administration of a single dose (25 nmol/kg of body weight), with 96% of the dose ultimately excreted at the first urination with no chemical modification. Furthermore, urine containing CD-NIR-1 in ureters showed strong NIRF, thereby enabling IUI and IUD via NIRF imaging. These results demonstrated the efficacy of CD-NIR-1 for clinical use.
More Related Videos
09:50Detection of Tissue-resident Bacteria in Bladder Biopsies by 16S rRNA Fluorescence In Situ Hybridization
Published on: October 18, 2019
06:37Multispectral Real-time Fluorescence Imaging for Intraoperative Detection of the Sentinel Lymph Node in Gynecologic Oncology
Published on: October 20, 2010
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Urologic Endoscopic Procedure: Cystoscopic Examination