Related Experiment Video
Updated: Dec 21, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
A liquid-crystal-based immunosensor for the detection of cardiac troponin I
Chunli Xia1, Dong Zhou, Yueming Su
1Key Lab of In-fiber Integrated Optics, Ministry Education of China, Harbin Engineering University, Harbin 150001, China. liuyj@hrbeu.edu.cn.
Abstract:
Cardiac troponin I (cTnI) is one of the most sensitive and specific markers of myocardial cell injury, which can detect even minor myocardial damages. It is recognized as the main biochemical marker of the rapid diagnosis of acute myocardial infarction (AMI) and acute coronary syndrome (ACS). In this study, a label-free biosensor that utilizes the birefringence property of a nematic liquid crystal (LC) for the detection of cTnI is demonstrated. A chemically sensitive film with specific molecular recognition ability was decorated on the surface of a substrate, and the LC molecules were arranged in a vertically oriented order under the influence of the sensitive film, and a dark background signal was obtained using a polarizing optical microscope. When the antigen-antibody specifically binds to form a stronger acting force, the orientation of the LC molecules changes, resulting in a bright optical appearance. This LC-based immunosensor not only has the advantages of a facile structure, low cost and excellent specificity but also high sensitivity (a low detection limit of 1 pg ml-1), and has a promising future in biomedical related fields.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
08:58Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood
Published on: April 16, 2016
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...