Related Experiment Video
Updated: Dec 20, 2025

High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
TICT-Based Near-Infrared Ratiometric Organic Fluorescent Thermometer for Intracellular Temperature Sensing
Lingchen Meng1, Shan Jiang1, Meiyu Song2
1State Key Laboratory of Supramolecular Structure and Materials, Jilin University, Changchun 130012, China.
Abstract:
Fluorescent thermometers with near-infrared (NIR) emission play an important role in visualizing the intracellular temperature with high resolution and investigating the cellular functions and biochemical activities. Herein, we designed and synthesized a donor-Π-acceptor luminogen, 2-([1,1'-biphenyl]-4-yl)-3-(4-((E)-4-(diphenylamino)styryl) phenyl) fumaronitrile (TBB) by Suzuki coupling reaction. TBB exhibited twisted intramolecular charge transfer-based NIR emission, aggregation-induced emission, and temperature-sensitive emission features. A ratiometric fluorescent thermometer was constructed by encapsulating thermosensitive NIR fluorophore TBB and Rhodamine 110 dye into an amphiphilic polymer matrix F127 to form TBB&R110@F127 nanoparticles (TRF NPs). TRF NPs showed a good temperature sensitivity of 2.37%·°C-1, wide temperature response ranges from 25 to 65 °C, and excellent temperature-sensitive emission reversibility. Intracellular thermometry experiments indicated that TRF NPs could monitor the cellular temperature change from 25 to 53 °C for Hep-G2 cells under the photothermal therapy agent heating process, indicating the considerable potential applications of TRF NPs in the biological thermometry field.
Related Concept Videos
Total Internal Reflection Fluorescence Microscopy
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Thermosensation
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...