Related Experiment Video
Updated: Dec 20, 2025

Breath Collection from Children for Disease Biomarker Discovery
Published on: February 14, 2019
Evaluation of a multiple breath nitrogen washout system in children
Sarah M Isaac1, Renee Jensen1, Pinelopi Anagnostopoulou2,3
1Translational Medicine, Research Institute, Hospital for Sick Children, Toronto, Canada.
Introduction:
The multiple breath nitrogen washout (MBW) test offers a sensitive measure of airway function. In this study we aim to (a) assess the validity of the EasyOne Pro LAB (MBWndd ) in an in vitro lung model, (b) assess the feasibility, repeatability, and reproducibility of MBWndd and (c) compare outcomes with the Exhalyzer D (MBWEM ) and body plethysmography.
Methods:
In vitro, functional residual capacity (FRC) measurements were assessed using a lung model under quasi-physiological conditions and compared to measured FRC. In vivo plethysmography and MBW were performed in a prospective study of children at two visits (n = 45 healthy; n = 41 cystic fibrosis [CF]). Bland-Altman plots were used to compare agreement between FRC and lung clearance index (LCI) measurements.
Results:
In vitro FRCndd measurements were repeatable but lung volumes were underestimated (mean relative difference -5.4% (limits of agreement [LA] -9.6%; -1.1%), 95% confidence interval (CI) -6.27; -4.45). In vivo, compared to plethysmography, FRCndd was consistently lower (-19.3% [-40.5; 1.9], 95% CI [-23.9; -14.7]), and showed a volume dependency. LCIndd values were also higher in children with smaller lung volumes. The within-test coefficient of variation of the FRCndd and LCIndd were 4.9% in health, and 5.6% and 6.9% in CF respectively. LCIndd was reproducible between-visits (mean relative difference [LA] -3.7% [-14.8, -7.5; 95% CI -6.6; -0.73] in health [n = 17] and 0.34% [-13.2, 22.8; 95% CI -5.0; 5.69] in CF [n = 23]). When calculated using the same algorithm, LCIndd was similar to LCIEM in health.
Conclusions:
MBWndd measurements are feasible, repeatable, and reproducible, however, MBW-derived outcomes are not interchangeable with MBWEM .
Related Concept Videos
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...