Classification of Intracranial Stenoses: Discrepancies between Transcranial Duplex Sonography and Computed Tomography
Leon Alexander Danyel1, Sara Hadzibegovic1, Jose Manuel Valdueza2
1Department of Neurology, University Hospital Charité, Berlin, Germany.
Abstract:
Transcranial color-coded duplex sonography (TCCS) and computed tomography angiography (CTA) are widely used to identify intracranial stenoses (ISs). We assessed concordance of IS grading between TCCS and CTA and proposed new TCCS criteria for severe IS ≥70%. One hundred two stroke patients (70 ± 13 y) with TCCS-identified IS were included. TCCS and CTA were performed within 24 h after admission. TCCS peak systolic velocity cutoffs for <50%/50%-69% stenoses were ≥155/≥220 cm/s (middle cerebral artery [MCA]-M1), ≥100/≥140 cm/s (MCA-M2), ≥120/≥155 cm/s (anterior cerebral artery [ACA]-A1), ≥100/≥145 cm/s (posterior cerebral artery [PCA]-P1 and PCA-P2), ≥90/≥120 cm/s (vertebral artery [VA]-V4) and ≥100/≥140 cm/s (basilar artery [BA]). Criteria for ≥70% stenoses were, despite variable flow velocities, post-stenotic flow alterations and/or leptomeningeal collateral flow. One hundred seventy-seven ISs were detected by TCCS. The number and grade (<50%/50%-69%/≥70%) of ISs were MCA 70 (39/19/12), BA 24 (9/11/4), ACA 21 (14/7/0), PCA 49 (29/15/5) and VA 13 (2/6/5). IS localization was confirmed by CTA in 84 of 177 cases (48%): MCA, 41/70 (59%); BA, 16/24 (67%); ACA 2/21, (10%); PCA, 17/49 (35%); VA, 8/13 (62%). Concordance between TCCS and CTA grading was (<50%/50%-69%/≥70%) 17%/19%/77%. TCCS and CTA exhibited substantial differences in the detection and grading of IS. Higher concordance rates for severe stenosis support our proposed TCCS criteria.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...