Quality performance for indirect Xa inhibitor monitoring in patients using international external quality data
Martine J Hollestelle1, Felix J M van der Meer2, Piet Meijer1
1External Quality Control for Assays and Tests (ECAT) Foundation, Voorschoten, The Netherlands.
Abstract:
Objectives Chromogenic anti-activated factor X (FXa) assays are currently the "gold standard" for monitoring indirect anticoagulants. However, anti-FXa has been shown to vary according to the choice of reagents. In the present study, the performance of anti-FXa measurement was evaluated in order to gain more insight into the clinical applications. Furthermore, the longitudinal coefficient of variation (CV) was studied to investigate whether there is improvement over time. Methods Laboratory tests results were evaluated for samples spiked with unfractionated heparin (UFH), low-molecular-weight-heparin (LMWH), fondaparinux and danaparoid sodium. External quality assessment (EQA) data from multiple years were used from more than 100 laboratories. Results Comparison of the results for all methods showed significant differences in measured values between the frequently used methods (ANOVA: p < 0.001). The largest differences were observed for LMWH and UFH measurements. These differences may be caused by differences in method composition, such as the addition of dextran sulphate. Substantial interlaboratory variation in anti-FXa monitoring was observed for all parameters, particularly at low concentrations. Our results showed that below 0.35 IU/mL, the CVs for UFH and LMWH increase dramatically and results below this limit should be used with caution. Conclusions Our study demonstrates that the choice of the anti-FXa method is particularly important for UFH and LMWH measurement. The variation in measurements may have an effect on clinical implications, such as therapeutic ranges. Furthermore, the longitudinal EQA data demonstrated a constant performance and, in at least 50% of the cases, improvement in the CV% of the anti-Xa results over time.
Related Concept Videos
Therapeutic Drug Monitoring: Drug Analysis Methods
Drug Product Performance: In Vitro–In Vivo Correlation
Therapeutic Drug Monitoring: Affecting Factors
The X̄ Chart
The x̄ chart, often known as the individual control chart, is a crucial tool in statistical process control. It is designed to monitor process behavior and performance over time and is widely used in various industries to ensure that processes are operating at their optimum capacity and within specified limits.
A x̄ chart is constructed by plotting individual measurements of a quality...
Therapeutic Drug Monitoring: Overview and Classification
Dosage Regimen: Individualization