Objective:
To investigate the value of 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in the evaluation of spinal giant cell tumors (GCTs).
Materials And Methods:
The PET/CT and clinical data of 16 patients with spinal GCTs were reviewed. The maximal standardized uptake value (SUVmax), longest diameter, and CT features of spinal GCTs were analyzed. The value of PET/CT and MRI in displaying the recurrent lesions was compared. PET Response Criteria in Solid Tumors were adopted to evaluate the response to radiotherapy.
Results:
Data from 7 males and 9 females (median age 32.5 years) were analyzed. Eight patients had primary GCTs with a median SUVmax of 11.91 and a median length of 4.42 cm. Eight patients had relapsed GCTs with a median SUVmax of 10.34 and a median length of 6.23 cm. There was no statistical difference between the SUVmax of primary and relapsed GCTs. The SUVmax did not correlate with length. In 8 relapsed patients, 4 lesions invaded the vertebral canal, but 2 of which were not displayed on MRI. Metal prostheses showed extremely low signal intensity on MRI, even in the 3 cases with increased intra-prosthetic 18F-FDG concentration. Five relapsed patients with subsequent radiotherapy had a repeat PET/CT. A complete, partial, and stable metabolic response was observed in 1, 3, and 1 patient, respectively.
Conclusions:
Both the primary and recurrent spinal GCTs avidly accumulate 18F-FDG. For recurrent GCTs, PET/CT may provide incremental value in the assessment of the vertebral canal and intra-prosthetic involvement and the response to radiotherapy.
More Related Videos
12:24Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET