Related Experiment Video
Updated: Dec 20, 2025

Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
Published on: April 21, 2019
Accuracy of penicillin allergy diagnostic tests: A systematic review and meta-analysis
Bernardo Sousa-Pinto1, Isabel Tarrio2, Kimberly G Blumenthal3
1MEDCIDS, Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal; CINTESIS, Center for Health Technology and Services Research, Faculty of Medicine, University of Porto, Porto, Portugal; Basic and Clinical Immunology Unit, Department of Pathology, Faculty of Medicine, University of Porto, Porto, Portugal.
Background:
Having a penicillin allergy label associates with a higher risk for antibiotic resistance and increased health care use.
Objective:
We sought to assess the accuracy of skin tests and specific IgE quantification in the diagnostic evaluation of patients reporting a penicillin/β-lactam allergy.
Methods:
We performed a systematic review and diagnostic accuracy meta-analysis, searching on MEDLINE, Scopus, and Web of Science. We included studies conducted in patients reporting a penicillin allergy and in whom skin tests and/or specific IgE quantification were performed and compared with drug challenge results. We quantitatively assessed the accuracy of diagnostic tests with bivariate random-effects meta-analyses. Meta-regression and subgroup analyses were performed to explore causes of heterogeneity. Studies' quality was evaluated using QUADAS-2 criteria.
Results:
We included 105 primary studies, assessing 31,761 participants. Twenty-seven studies were assessed by bivariate meta-analysis. Skin tests had a summary sensitivity of 30.7% (95% CI, 18.9%-45.9%) and a specificity of 96.8% (95% CI, 94.2%-98.3%), with a partial area under the summary receiver-operating characteristic curve of 0.686 (I2 = 38.2%). Similar results were observed for subanalyses restricted to patients reporting nonimmediate maculopapular exanthema or urticaria/angioedema. Specific IgE had a summary sensitivity of 19.3% (95% CI, 12.0%-29.4%) and a specificity of 97.4% (95% CI, 95.2%-98.6%), with a partial area under the summary receiver-operating characteristic curve of 0.420 (I2 = 8.5%). Projected predictive values mainly reflect the low frequency of true penicillin allergy.
Conclusions:
Skin tests and specific IgE quantification appear to have low sensitivity and high specificity. Because current evidence is insufficient for assessing the role of these tests in stratifying patients for delabeling, we identified key requirements needed for future studies.
Related Concept Videos
Allergic Reactions
Pneumonia III: Complications and Assessment
Allergic Drug Reactions
Cross-reactivity