Related Experiment Video
Updated: Dec 20, 2025

Development of a More Sensitive and Specific Chromogenic Agar Medium for the Detection of Vibrio parahaemolyticus and Other Vibrio Species
Published on: November 8, 2016
An improved recombinase polymerase amplification assay for visual detection of Vibrio parahaemolyticus with lateral
Xiaohan Yang1, Panpan Zhao2, Yu Dong1
1Jiangsu Key Laboratory of Marine Biological Resources and Environment, Jiangsu Key Laboratory of Marine Pharmaceutical Compound Screening, Co-Innovation Center of Jiangsu Marine Bio-industry Technology, Jiangsu Ocean University, Lianyungang, China.
Abstract:
Vibrio parahaemolyticus is an important pathogenic bacterium in both food safety management and mariculture. Rapid and accurate detection technologies are critical for effective control of its outbreak and spreading. Conventional technologies and polymerase chain reaction (PCR)-based approaches have limited usage because of the requirement of laboratory instruments and trained personnel. Using the isothermal recombinase polymerase amplification (RPA) technology, several detection assays have been developed with added convenience. Combining the lateral flow strip (LFS) test with RPA can further simplify the detection. In this study, an improved RPA assay using LFS for visual detection of V. parahaemolyticus was developed. Primers were designed targeting the virulence genes and screened for amplification efficiency, nonspecific amplification, and primer-dimer formation. Probes were designed for the best primer pairs, and the weakness of LFS tests, being easily affected by primer-dependent artifacts, was overcome by sequence modifications on primers and probe. The RPA-LFS assay took 25 min at 35 to 45 °C, and showed excellent specificity. It detected as low as one colony forming unit (CFU) of V. parahaemolyticus per reaction without DNA purification, or 10 CFU/10 g spiked food samples with 2 hr of enrichment. The detection limit was better than the currently available RPA-based detection methods. Application of the RPA-LFS assay for simulated samples or real clinical samples showed accurate and consistent detection results compared to bioassay and quantitative PCR. The RPA-LFS assay provided a rapid, accurate, and convenient V. parahaemolyticus detection method suitable for on-site detection in resource-limited conditions. PRACTICAL APPLICATION: This research developed a rapid and visual detection technology for Vibrio parahaemolyticus that is not dependent on complicated equipment. The detection process takes 25 min and the result is read with the naked eye. A detection kit can be developed based on this technology for on-site detection of V. parahaemolyticus in resource-limited regions for food safety management and mariculture.
More Related Videos
06:18Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018
07:47Reverse Transcription Loop-Mediated Isothermal Amplification RT-LAMP Assay for the Specific and Rapid Detection of Tilapia Lake Virus
Published on: May 18, 2020