Related Experiment Video
Updated: Dec 20, 2025

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Reassessment of the Location of the Conduction System in Atrioventricular Septal Defect Using Phase-Contrast Computed
Shuichi Yoshitake1, Yukihiro Kaneko2, Kiyozo Morita3
1Division of Cardiovascular Surgery, National Center for Child Health and Development, Tokyo, Japan; Department of Pediatric Cardiac Surgery, University of Rochester, Rochester, New York.
Abstract:
The location of the atrioventricular conduction axis in the setting of atrioventricular septal defect has previously been shown by histology and intraoperative recordings. We have now reassessed the arrangement using phase-contrast computed tomography, aiming to provide precise measurements so as to optimize future surgical repairs. We used the system based on an X-ray Talbot grating interferometer using the beamline BL20B2 in a SPring-8 synchrotron radiation facility available in Japan. We analyzed 18 specimens. The atrioventricular node was found within a nodal triangle 1.7 mm from the coronary sinus, with 95% confidence intervals from 1.45 to 2.0 millimeters. The depth of the node from the right atrial endocardium was 1.0 mm, with 95% confidence intervals from 0.73 to 1.34 mm. The overall length of the scooped-out ventricular septum was 30.8 mm, with 95% confidence intervals from 27.5 to 34.1 millimeters. The length from the inferior atrioventricular junction to the take-off of the right bundle branch was 12.8 mm, with 95% confidence intervals from 11.12 to 14.38 mm, giving a ratio of 0.43 for the extent of the axis along the inferior septum, with 95% confidence intervals of 0.38-0.48. The length of the non-branching bundle was 6.6 mm, with 95% confidence intervals from 5.57 to 7.7 mm. The proportion of septum occupied by the non-branching bundle was 0.22, with 95% confidence intervals from 0.18 to 0.26. Our findings confirm previous histological studies, extending them by providing precise measurements to guide placement of sutures during surgical repair.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Mitral Stenosis II: Clinical features and Diagnostic Tests