Related Experiment Video
Updated: Dec 20, 2025

Observation of the Ciliary Movement of Choroid Plexus Epithelial Cells Ex Vivo
Published on: July 13, 2015
Predicting the Ideal Ventricular Freehand Pass Trajectory Using Osirix Software and the Role of Occipital Shape
Harsh Deora1, Nupur Pruthi1, Kannepalli V L N Rao1
1Department of Neurosurgery, National Institute of Mental Health and Neurosciences, Bangalore, India.
Background:
Cannulation of lateral ventricles via a posterior approach is a common neurosurgical procedure. It is often believed that a single entry and fiducial point applies to all. No importance is given to skull shape variations, which can lead to wrong shunt positions and revisions.
Objective:
A virtual-reality study was conducted to find the ideal entry point, ideal forehead fiducial point, and ideal angulation of the ventricular catheter and variations in these with changes in skull shapes.
Methods:
Fifty human cadaveric skulls were used to measure anteroposterior (AP) diameter and width and to classify shape of skulls into 4 types. Hydrocephalus (100 cases) and normal magnetic resonance images (50 cases) were studied from a PACS (Picture Archiving and Communication System) database. An Osirix DICOM Viewer (3.9.4) was used to reconstruct the images and estimate the ideal, 90°, and midline shunt trajectory and correlate the same with AP/width ratios and skull shapes.
Results:
Contrary to popular practice, the vertical distance from the inion for ideal trajectory placement was <6 cm and >4 cm in all shapes and ratio groups for hydrocephalus and nonhydrocephalus cases, respectively. As the AP/width ratio increases, the fiducial needs to be placed at a higher distance from the nasion and the distance of the entry point also increased from the inion. A rounder or more dolichocephalic skull dictates a 90° approach to be better, especially as the first pass.
Conclusions:
No magical external entry point uniformly applicable for all cases exists. Hence, there is a need to classify skulls according to shapes/ratios and to use a tailored approach for a freehand pass to cannulate the ventricles.
More Related Videos
Related Concept Videos
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...

